Item Name | Resistor Fixed Wire Wound Induct |
Federal Supply Group (FSG) | Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5905 Resistors |
National Item Identification Number (NIIN) | 00-617-9806 (006179806) |
NCB Code | USA (00) |
Manufacturer | Heico Ohmite Llc, Milwaukee Resistor Corporation, Ward Leonard Electric Company Inc, Basler Electric Company, Stone Safety Corp, Harris Corporation, Drs Power And Control Technologies, Westinghouse Electric Corp, C Systems Llc, Regulators Products Group Of Ward |
Part Number | Manufacturer | Item Name | Cage Code | RFQ |
---|---|---|---|---|
43062-1500HM | heico ohmite llc | resistor fixed wire wound induct | 44655 | RFQ |
10-32-150S | milwaukee resistor corporation | resistor fixed wire wound induct | 82807 | RFQ |
25954-3-106 | ward leonard electric company inc | resistor fixed wire wound induct | 63743 | RFQ |
69-1447 | basler electric company | resistor fixed wire wound induct | 97520 | RFQ |
X1029PC7 | stone safety corp | resistor fixed wire wound induct | 08219 | RFQ |
4306225W1500HM | heico ohmite llc | resistor fixed wire wound induct | 44655 | RFQ |
FSN31847-1-110 | harris corporation | resistor fixed wire wound induct | 28527 | RFQ |
K45258-150 | ward leonard electric company inc | resistor fixed wire wound induct | 63743 | RFQ |
2A239TVIT150OHM | ward leonard electric company inc | resistor fixed wire wound induct | 63743 | RFQ |
X1030PC6 | stone safety corp | resistor fixed wire wound induct | 08219 | RFQ |
69-1447 | drs power and control technologies | resistor fixed wire wound induct | 27192 | RFQ |
16999-81500HMS | ward leonard electric company inc | resistor fixed wire wound induct | 63743 | RFQ |
X1050PC35 | stone safety corp | resistor fixed wire wound induct | 08219 | RFQ |
917J713PC43 | westinghouse electric corp | resistor fixed wire wound induct | 11660 | RFQ |
J81-0300 | ward leonard electric company inc | resistor fixed wire wound induct | 20019 | RFQ |
CSR31 | c systems llc | resistor fixed wire wound induct | 088a2 | RFQ |
X1028PC6 | stone safety corp | resistor fixed wire wound induct | 08219 | RFQ |
X1027PC7 | stone safety corp | resistor fixed wire wound induct | 08219 | RFQ |
T5873-15 | stone safety corp | resistor fixed wire wound induct | 08219 | RFQ |
A745-41-63 | regulators products group of ward | resistor fixed wire wound induct | 02574 | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
AAPP | ELECTRICAL RESISTANCE | 150.000 OHMS |
AAPQ | RESISTANCE TOLERANCE IN PERCENT | -10.000 TO 10.000 |
AAQG | AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER | 350.0 |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABJT | TERMINAL LENGTH | 0.652 INCHES NOMINAL |
ABPM | BODY DIAMETER | 0.625 INCHES NOMINAL |
ADAQ | BODY LENGTH | 1.968 INCHES MINIMUM AND 2.031 INCHES MAXIMUM |
AEFB | POWER DISSIPATION RATING IN WATTS | 25.000 FREE AIR |
AEHY | AMBIENT TEMP AT FULL RATED POWER | 50.0 DEG CELSIUS |
AFWW | TERMINAL WIDTH | 0.250 INCHES NOMINAL |
AKNA | INCLOSURE TYPE | ENCAPSULATED |
CBME | CUBIC MEASURE | 0.623 CUBIC INCHES |
CSCF | TERMINAL TYPE | TAB W/SCREW |
STYL | STYLE DESIGNATOR | RADIAL TERMINAL EACH END |
ZZZT | NONDEFINITIVE SPEC/STD DATA | IW FORM |
Relevant Components for NSN - 5905-00-617-9806, 5905006179806 | ||||
5975-01-629-6429 (5975016296429) | 5998-01-305-2341 (5998013052341) | 5930-01-584-0809 (5930015840809) | 5962-01-210-3065 (5962012103065) | |
5905-00-175-4284 (5905001754284) | 5950-01-458-0903 (5950014580903) | 5920-01-490-0904 (5920014900904) | 5998-01-475-9891 (5998014759891) | |
5995-01-575-7529 (5995015757529) | 5962-01-310-7304 (5962013107304) | 5935-01-240-1468 (5935012401468) | 5995-01-374-0247 (5995013740247) | |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote