MRC | Criteria | Characteristic |
---|
ABHP | OVERALL LENGTH | 1.000 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 2.562 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 0.670 INCHES NOMINAL |
ADAR | BODY OUTSIDE DIAMETER | 0.437 INCHES NOMINAL |
ADAU | BODY HEIGHT | 1.650 INCHES NOMINAL |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.128 INCHES NOMINAL |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 0.750 INCHES NOMINAL |
AECR | VIBRATION RESISTANCE RANGE IN HERTZ | 10.0 TO 55.0 |
AFGA | OPERATING TEMP RANGE | -30.0 TO 85.0 DEG CELSIUS |
AHAJ | REFERENCE FREQUENCY PER FUNCTION | 501.9 KILOHERTZ 1ST BAND PASS 1ST FUNCTION |
AHAJ | REFERENCE FREQUENCY PER FUNCTION | 501.9 KILOHERTZ 2ND BAND PASS 2ND FUNCTION |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 1ST BAND PASS 1ST FUNCTION |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 2ND BAND PASS 2ND FUNCTION |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 1ST BAND PASS 1ST FUNCTION |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 2ND BAND PASS 2ND FUNCTION |
AHBX | DISTANCE BETWEEN MOUNTING SURFACE AND LOWER END | 0.7212 INCHES NOMINAL |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 UNTHREADED HOLE |
CQDR | INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | 5.5 1ST BAND PASS 1ST FUNCTION |
CQDR | INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | 5.5 2ND BAND PASS 2ND FUNCTION |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 TAB,SOLDER LUG GROUND 3RD FUNCTION |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 2 TAB,SOLDER LUG INPUT 1ST FUNCTION |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 2 TAB,SOLDER LUG OUTPUT 2ND FUNCTION |
CQFC | SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | 499.20 KILOHERTZ 1ST BAND PASS AND 500.30 KILOHERTZ 1ST BAND PASS AND 503.50 KILOHERTZ 1ST BAND PASS AND 505.30 KILOHERTZ 1ST BAND PASS 1ST FUNCTION |
CQFC | SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | 499.20 KILOHERTZ 2ND BAND PASS AND 500.30 KILOHERTZ 2ND BAND PASS AND 503.50 KILOHERTZ 2ND BAND PASS AND 505.30 KILOHERTZ 2ND BAND PASS 2ND FUNCTION |
CRBB | FREQUENCY BAND WIDTH PER FUNCTION | 500.30 KILOHERTZ 1ST BAND PASS AND 503.50 KILOHERTZ 1ST BAND PASS 1ST FUNCTION |
CRBB | FREQUENCY BAND WIDTH PER FUNCTION | 500.30 KILOHERTZ 2ND BAND PASS AND 503.50 KILOHERTZ 2ND BAND PASS 2ND FUNCTION |
CRBC | DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | 60.0 MINIMUM 1ST BAND PASS AND 3.0 MAXIMUM 1ST BAND PASS 1ST FUNCTION |
CRBC | DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | 60.0 MINIMUM 2ND BAND PASS AND 3.0 MAXIMUM 2ND BAND PASS 2ND FUNCTION |
CRDC | MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE | 100.0 VOLTS AT SEA LEVEL |
CRST | BODY SURFACE TREATMENT | TIN |
STYL | STYLE DESIGNATOR | ROUND TERMINAL/TERMINALS ON OPPOSITE SURFACES |