Aerospace Engineering Solutions is proud to offer immediate purchasing options on International Power Sources Inc part number ALPHA 3807-01GD, a Powersupply product we carry that is listed with the NSN 6130-01-398-9105 for ease of identification. If you would like to learn more about this item, be sure to complete the Request for Quote (RFQ) form provided on this page. By including essential details like your target price, desired quantity, and expected fulfillment timeline, you are ensured a fully customized quote from our team.
Note : We Will Not Share Your Information To Any Third Parties.
For your reference, this product is traceable to International Power Sources Inc through the CAGE Code 0JSW7, as well as categorized under FSC 6130 Converters Electrical Non Rotating based on the first four digits of the NSN 6130-01-398-9105. Using such information, you can easily narrow down exact items of need for an ease of procurement. With our quotation service in mind, be sure to submit a completed form when you are ready to begin. Should you wish to speak with one of our representatives to discuss services, you can also give us a call or email at your convenience. With all that we offer, choose Aerospace Engineering Solutions for part number ALPHA 3807-01GD and other NSN items of need.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
6130-01-398-9105 Item PartTypeName: POWER SUPPLY | 6130 | 013989105 | 0 | N | B | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | B | A | 0 | |||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
ALPHA 3807-01GD | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
ANPM | INPUT PHASE | SINGLE 2ND ALTERNATE OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 220.0 AC POUNDS PER HOUR DRY 3RD ALTERNATE OPERATING POWER RQMT AND 230.0 AC POUNDS PER HOUR WITH RETAINING CHAIN 3RD ALTERNATE OPERATING POWER RQMT |
APTQ | INPUT FREQUENCY RATING | 48.0 HERTZ MINIMUM 2ND ALTERNATE OPERATING POWER RQMT AND 62.0 HERTZ MAXIMUM 2ND ALTERNATE OPERATING POWER RQMT |
CRTL | CRITICALITY CODE JUSTIFICATION | FEAT |
CWHC | OUTPUT CONTROL LOCATION | REAR PANEL SINGLE POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | CONNECTOR,RECEPTACLE SINGLE POWER OUTPUT |
CWHM | INPUT CURRENT RATING | 70.0 AC AMPERES NOMINAL 3RD ALTERNATE OPERATING POWER RQMT |
CWHT | INPUT CONNECTION QUANTITY | 1 2ND ALTERNATE OPERATING POWER RQMT |
ABKW | OVERALL HEIGHT | 5.250 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 13.110 INCHES NOMINAL |
ANPM | INPUT PHASE | SINGLE 1ST ALTERNATE OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 120.0 AC POUNDS PER HOUR DRY 2ND ALTERNATE OPERATING POWER RQMT AND 130.0 AC POUNDS PER HOUR WITH RETAINING CHAIN 2ND ALTERNATE OPERATING POWER RQMT |
CWKG | VENTILATION DESIGN TYPE | CONVECTION |
ABHP | OVERALL LENGTH | 19.000 INCHES NOMINAL |
AGAV | END ITEM IDENTIFICATION | F-15 |
AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
ANPM | INPUT PHASE | SINGLE 3RD ALTERNATE OPERATING POWER RQMT |
ANPM | INPUT PHASE | SINGLE 4TH ALTERNATE OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 230.0 AC POUNDS PER HOUR DRY 4TH ALTERNATE OPERATING POWER RQMT AND 250.0 AC POUNDS PER HOUR WITH RETAINING CHAIN 4TH ALTERNATE OPERATING POWER RQMT |
APPA | OUTPUT VOLTAGE RATING | 0.0 DC KILOVOLTS MINIMUM SINGLE POWER OUTPUT AND 30.0 DC KILOVOLTS MAXIMUM SINGLE POWER OUTPUT |
APTQ | INPUT FREQUENCY RATING | 48.0 HERTZ MINIMUM 1ST ALTERNATE OPERATING POWER RQMT AND 62.0 HERTZ MAXIMUM 1ST ALTERNATE OPERATING POWER RQMT |
APTQ | INPUT FREQUENCY RATING | 48.0 HERTZ MINIMUM 3RD ALTERNATE OPERATING POWER RQMT AND 62.0 HERTZ MAXIMUM 3RD ALTERNATE OPERATING POWER RQMT |
APTQ | INPUT FREQUENCY RATING | 48.0 HERTZ MINIMUM 4TH ALTERNATE OPERATING POWER RQMT AND 62.0 HERTZ MAXIMUM 4TH ALTERNATE OPERATING POWER RQMT |
CWGH | OUTPUT CURRENT RATING | 0.0 DC MILLIAMPERES MINIMUM SINGLE POWER OUTPUT AND 1.5 DC MILLIAMPERES MAXIMUM SINGLE POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 1 SINGLE POWER OUTPUT |
CWHM | INPUT CURRENT RATING | 70.0 AC AMPERES NOMINAL 1ST ALTERNATE OPERATING POWER RQMT |
CWHM | INPUT CURRENT RATING | 70.0 AC AMPERES NOMINAL 2ND ALTERNATE OPERATING POWER RQMT |
CWHM | INPUT CURRENT RATING | 70.0 AC AMPERES NOMINAL 4TH ALTERNATE OPERATING POWER RQMT |
CWHT | INPUT CONNECTION QUANTITY | 1 1ST ALTERNATE OPERATING POWER RQMT |
CWHT | INPUT CONNECTION QUANTITY | 1 3RD ALTERNATE OPERATING POWER RQMT |
CWHT | INPUT CONNECTION QUANTITY | 1 4TH ALTERNATE OPERATING POWER RQMT |
FEAT | SPECIAL FEATURES | OUTPUT VOLTAGE ANALOG METER,CONTROL SELECTOR SWITCH,VOLTAGE AND CURRENT ADJUSTABLE,LOCAL CONTROL POTENTIOMETER,ELECTROSTATIC SENSITIVE DEVICE |
APNX | INPUT VOLTAGE RATING | 90.0 AC POUNDS PER HOUR DRY 1ST ALTERNATE OPERATING POWER RQMT AND 110.0 AC POUNDS PER HOUR WITH RETAINING CHAIN 1ST ALTERNATE OPERATING POWER RQMT |
AYNH | OPERATING AMBIENT TEMP RANGE | 0.1/50.0 DEG CELSIUS |