Aerospace Engineering Solutions is proud to offer immediate purchasing options on Microwave Engineering Corporation part number TFT86007, a Waveguide Assembly product we carry that is listed with the NSN 5985-00-005-2961 for ease of identification. If you would like to learn more about this item, be sure to complete the Request for Quote (RFQ) form provided on this page. By including essential details like your target price, desired quantity, and expected fulfillment timeline, you are ensured a fully customized quote from our team.
Note : We Will Not Share Your Information To Any Third Parties.
For your reference, this product is traceable to Microwave Engineering Corporation through the CAGE Code 06351, as well as categorized under FSC 5985 Antennas Waveguides and Related Equipment based on the first four digits of the NSN 5985-00-005-2961. Using such information, you can easily narrow down exact items of need for an ease of procurement. With our quotation service in mind, be sure to submit a completed form when you are ready to begin. Should you wish to speak with one of our representatives to discuss services, you can also give us a call or email at your convenience. With all that we offer, choose Aerospace Engineering Solutions for part number TFT86007 and other NSN items of need.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5985-00-005-2961 Item PartTypeName: WAVEGUIDE ASSEMBLY | 5985 | 000052961 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
7 | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
TFT86007 | 6 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AAGR | CROSS-SECTIONAL SHAPE STYLE | INTERNAL,RECTANGULAR EXTERNAL,RECTANGULAR |
AAJD | THREAD CLASS | 2A FIRST FLANGE ALL CONNECTION FACILITIES |
AAJF | THREAD DIRECTION | RIGHT-HAND FIRST FLANGE ALL CONNECTION FACILITIES |
AHRV | TUBING WALL CONSTRUCTION STYLE | CORRUGATED SINGLE TUBING SEGMENT |
AHSF | FLANGE QUANTITY | 2 |
AHSX | FLANGE INSIDE WIDTH | 2.840 INCHES NOMINAL FIRST FLANGE |
AHSX | FLANGE INSIDE WIDTH | 3.002 INCHES NOMINAL SECOND FLANGE |
AHSY | FLANGE INSIDE HEIGHT | 1.340 INCHES NOMINAL FIRST FLANGE |
AHSY | FLANGE INSIDE HEIGHT | 1.502 INCHES NOMINAL SECOND FLANGE |
AHTC | FLANGE OUTSIDE DIAMETER | 5.313 INCHES NOMINAL FIRST FLANGE |
AHTC | FLANGE OUTSIDE DIAMETER | 5.313 INCHES NOMINAL SECOND FLANGE |
AHTD | FLANGE DEPTH | 0.750 INCHES NOMINAL FIRST FLANGE |
AHTD | FLANGE DEPTH | 1.250 INCHES NOMINAL SECOND FLANGE |
AHTN | FLANGE CONNECTING HOLE DIAMETER | 0.256 INCHES NOMINAL SECOND FLANGE ALL CONNECTION FACILITIES |
AHTW | VOLTAGE STANDING WAVE RATIO | 1.25 |
AHTX | INSERTION LOSS IN DECIBELS | 0.17 |
CQGM | MAXIMUM OPERATING PRESSURE | 26.0 POUNDS PER SQUARE INCH GAGE |
CQHN | WAVEGUIDE OUTSIDE WIDTH | 3.000 INCHES NOMINAL |
CQJX | NOMINAL THREAD SIZE | 0.250 INCHES FIRST FLANGE ALL CONNECTION FACILITIES |
CRFH | WAVEGUIDE INSIDE WIDTH | 2.840 INCHES NOMINAL |
CRLB | WAVEGUIDE INSIDE HEIGHT | 1.340 INCHES NOMINAL |
CSFC | WAVEGUIDE OUTSIDE HEIGHT | 1.500 INCHES NOMINAL |
CSQT | FLANGE CONNECTING FACILITY AND QUANTITY | 8 THREADED HOLE FIRST FLANGE ALL CONNECTION FACILITIES |
CSQT | FLANGE CONNECTING FACILITY AND QUANTITY | 8 UNTHREADED HOLE SECOND FLANGE ALL CONNECTION FACILITIES |
CTCJ | FLANGE STYLE | CHOKE TYPE FIRST FLANGE |
CTCJ | FLANGE STYLE | COVER TYPE SECOND FLANGE |
CTFD | WAVEGUIDE LENGTH | 3.938 FEET NOMINAL |
FLEX | FLEXIBILITY | FLEXIBLE SINGLE TUBING SEGMENT |
MATT | MATERIAL | ALUMINUM SINGLE TUBING SEGMENT |
MATT | MATERIAL | PLASTIC SINGLE TUBING JACKET |
SFTT | SURFACE TREATMENT | CHROMATE ALL FLANGE OUTSIDE SURFACESANY ACCEPTABLE ALL FLANGE INSIDE SURFACES |
STYL | STYLE DESIGNATOR | STRAIGHT TYPE |
THSD | THREAD SERIES DESIGNATOR | UNC FIRST FLANGE ALL CONNECTION FACILITIES |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.