Aerospace Engineering Solutions is proud to offer immediate purchasing options on Military Specifications part number MILR22097-1, a Resistor Variable Nonwire Wound product we carry that is listed with the NSN 5905-00-769-7320 for ease of identification. If you would like to learn more about this item, be sure to complete the Request for Quote (RFQ) form provided on this page. By including essential details like your target price, desired quantity, and expected fulfillment timeline, you are ensured a fully customized quote from our team.
Note : We Will Not Share Your Information To Any Third Parties.
For your reference, this product is traceable to Military Specifications through the CAGE Code 81349, as well as categorized under FSC 5905 Resistors based on the first four digits of the NSN 5905-00-769-7320. Using such information, you can easily narrow down exact items of need for an ease of procurement. With our quotation service in mind, be sure to submit a completed form when you are ready to begin. Should you wish to speak with one of our representatives to discuss services, you can also give us a call or email at your convenience. With all that we offer, choose Aerospace Engineering Solutions for part number MILR22097-1 and other NSN items of need.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5905-00-769-7320 Item PartTypeName: RESISTOR,VARIABLE,NONWIRE WOUND | 5905 | 007697320 | N | A | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
A | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
RJ11BP503 | 1 | 2 | 2 |
MRC | Criteria | Characteristic |
---|---|---|
CRFJ | TEMP COEFFICIENT OF RESISTANCE PER SECTION IN PPM PER DEG CELSIUS | -600.0 TO 600.0 SINGLE SECTION |
CRGD | POWER DISSIPATION RATING PER SECTION IN WATTS | 0.25 FREE AIR SINGLE SECTION |
CRSS | RESISTANCE TOLERANCE PER SECTION IN PERCENT | -10.0 TO 10.0 SINGLE SECTION |
TEST | TEST DATA DOCUMENT | 81349-MILR22097-1 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS,BROCHURES,ETC.,THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS,INDUSTRY DIRECTORIES,AND SIMILAR TRADE PUBLICATIONS,REFLECTI |
ABTB | MOUNTING HOLE DIAMETER | 0.088 INCHES MINIMUM AND 0.098 INCHES MAXIMUM |
ABWV | SHAFT DIAMETER | 0.100 INCHES MINIMUM AND 0.140 INCHES MAXIMUM |
ADAQ | BODY LENGTH | 1.218 INCHES MINIMUM AND 1.282 INCHES MAXIMUM |
AEDX | SHAFT STYLE | ROUND,SLOTTED |
AEFD | ACTUATOR TYPE | SINGLE SHAFT |
AEFH | EFFECTIVE ELECTRICAL ROTATION IN DEG ANGULAR ROTATION | 6120.0 MINIMUM AND 9720.0 MAXIMUM |
AEFK | MAXIMUM STARTING TORQUE | 8.00 INCH-OUNCES |
AGTP | LATERAL DISTANCE BETWEEN MOUNTING HOLE CENTERS | 0.109 INCHES MINIMUM AND 0.160 INCHES MAXIMUM |
CRSX | ACTUATOR TRAVEL CONTROL FEATURE | CLUTCH |
CSDH | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT FULL RATED POWER | 70.0 SINGLE SECTION |
TTQY | TERMINAL TYPE AND QUANTITY | 3 PIN |
AAPN | SECTION QUANTITY | 1 |
AAQL | BODY STYLE | RECTANGULAR W/MOUNTING HOLES/SLOTS |
ABHP | OVERALL LENGTH | 1.254 INCHES MINIMUM AND 1.359 INCHES MAXIMUM |
ABJT | TERMINAL LENGTH | 0.469 INCHES MINIMUM AND 0.624 INCHES MAXIMUM |
ABKW | OVERALL HEIGHT | 0.235 INCHES MINIMUM AND 0.300 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 0.235 INCHES MINIMUM AND 0.300 INCHES MAXIMUM |
ABXF | SHAFT LENGTH | 0.036 INCHES MINIMUM AND 0.077 INCHES MAXIMUM |
ADAT | BODY WIDTH | 0.235 INCHES MINIMUM AND 0.300 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 0.235 INCHES MINIMUM AND 0.300 INCHES MAXIMUM |
AEHT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.490 INCHES MINIMUM AND 0.510 INCHES MAXIMUM |
AKPV | MOUNTING FACILITY QUANTITY | 2 |
AXGY | MOUNTING METHOD | UNTHREADED HOLE |
AYQR | CENTER TO CENTER DISTANCE BETWEEN TERMINAL ROWS | 0.100 INCHES NOMINAL |
CQCC | ELECTRICAL RESISTANCE PER SECTION | 50.000 KILOHMS SINGLE SECTION |
CQCK | ROTARY ACTUATOR TRAVEL IN ANGULAR DEG | 6120.0 MINIMUM AND 9720.0 MAXIMUM |
CQCM | CENTER TO CENTER DISTANCE BETWEEN CENTER TERMINAL AND OUTSIDE TERMINAL | 0.290 INCHES MINIMUM AND 0.310 INCHES MAXIMUM |
CQGN | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT ZERO PERCENT RATED POWER | 125.0 SINGLE SECTION |
CQTM | TERMINAL LOCATION | LOWER ADJACENT SIDE SINGLE ROW |