Aerospace Engineering Solutions is proud to offer immediate purchasing options on Schneider Electric Gmbh part number 60180, a Circuit Breaker product we carry that is listed with the NSN 5925-01-593-1220 for ease of identification. If you would like to learn more about this item, be sure to complete the Request for Quote (RFQ) form provided on this page. By including essential details like your target price, desired quantity, and expected fulfillment timeline, you are ensured a fully customized quote from our team.
Note : We Will Not Share Your Information To Any Third Parties.
For your reference, this product is traceable to Schneider Electric Gmbh through the CAGE Code 56365, as well as categorized under FSC 5925 Circuit Breakers based on the first four digits of the NSN 5925-01-593-1220. Using such information, you can easily narrow down exact items of need for an ease of procurement. With our quotation service in mind, be sure to submit a completed form when you are ready to begin. Should you wish to speak with one of our representatives to discuss services, you can also give us a call or email at your convenience. With all that we offer, choose Aerospace Engineering Solutions for part number 60180 and other NSN items of need.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-593-1220 Item PartTypeName: CIRCUIT BREAKER | 5925 | 015931220 | 0 | P | A | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | A | 0 | |||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
60180 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AKPX | Pole Quantity | 3 |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 240.0 AC ALL LOCATIONS AND 125.0 DC ALL LOCATIONS |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
CPRJ | Trip Release Method | THERMAL-MAGNETIC ALL LOCATIONS |
CXCY | Part Name Assigned By Controlling Agency | INAVY: BREAKER 3 POLE 20A; CAGE: MINIATURE CIRCUIT BREAKER - C60N - 3 POLES - 20A - C CURVE |
CPRQ | Reset Method | MANUAL |
CRCF | Trip Release Ambient Temp Rating | -30.0 DEG CELSIUS MINIMUM ALL LOCATIONS AND 70.0 DEG CELSIUS MAXIMUM ALL LOCATIONS |
CPRW | Actuator Function | TRIP-RESET |
AXHR | Mounting Facility Type And Quantity | 35 MM SYMMETRICAL DIN RAIL |
CPRX | Actuator Position Designation | AT POLE ONE AND AT POLE TWO AND AT POLE THREE |
ADTV | Case Material | PLASTIC |
CPRY | External Actuator Linkage Arrangement | ONE, TWO, AND THREE LINKED |
ADAT | Body Width | 54.0 MILLIMETERS NOMINAL |
MRC | Decoded Requirement | Clear Text Reply |
ADAQ | Body Length | 107.0 MILLIMETERS NOMINAL |
AGAV | End Item Identification | MISC PARTS AUX SYS LCS 0002 |
ADAU | Body Height | 73.0 MILLIMETERS NOMINAL |
AAQL | Body Style | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
CPLM | Maximum Continuous Load Current Rating Per Pole | 20.0 AMPERES AC ALL LOCATIONS AND 20.0 AMPERES DC ALL LOCATIONS |
CPRT | Manual Actuator Type And Quantity | 3 TOGGLE |
TTQY | Terminal Type And Quantity | 6 SCREW |