Aerospace Engineering Solutions is proud to offer immediate purchasing options on Teledyne Reynolds Inc part number 421-6, a Relay Electromagnetic product we carry that is listed with the NSN 5945-01-349-5441 for ease of identification. If you would like to learn more about this item, be sure to complete the Request for Quote (RFQ) form provided on this page. By including essential details like your target price, desired quantity, and expected fulfillment timeline, you are ensured a fully customized quote from our team.
Note : We Will Not Share Your Information To Any Third Parties.
For your reference, this product is traceable to Teledyne Reynolds Inc through the CAGE Code 11532, as well as categorized under FSC 5945 Relays and Solenoids based on the first four digits of the NSN 5945-01-349-5441. Using such information, you can easily narrow down exact items of need for an ease of procurement. With our quotation service in mind, be sure to submit a completed form when you are ready to begin. Should you wish to speak with one of our representatives to discuss services, you can also give us a call or email at your convenience. With all that we offer, choose Aerospace Engineering Solutions for part number 421-6 and other NSN items of need.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5945-01-349-5441 Item PartTypeName: RELAY,ELECTROMAGNETIC | 5945 | 013495441 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
C1909-1 | 5 | 8 | E |
MRC | Criteria | Characteristic |
---|---|---|
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
AKDX | WINDING QUANTITY | 2 |
AKSL | PURPOSE FOR WHICH DESIGNED | GENERAL |
APCN | COIL QUANTITY | 2 |
APNQ | ARC QUENCHING METHOD | AIR |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 7 TERMINAL SINGLE MOUNTING FACILITY |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 500.0 MILLIAMPERES AC RESISTIVE LOAD AND 1.0 AMPERES DC RESISTIVE LOAD200.0 MILLIAMPERES DC INDUCTIVE LOAD100.0 MILLIAMPERES DC LAMP LOAD |
FEAT | SPECIAL FEATURES | FAILURE RATE 1.0 PERCENT PER 10,000 CYCLES |
TTQY | TERMINAL TYPE AND QUANTITY | 7 WIRE HOOK ALL FUNCTIONS |
ABHP | OVERALL LENGTH | 1.780 INCHES NOMINAL |
ADAV | OVERALL DIAMETER | 0.370 INCHES MAXIMUM |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
APNA | WINDING DC RESISTANCE RATING | 120.0 OHMS NOMINAL SINGLE WINDING |
APNP | DUTY TYPE | CONTINUOUS |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CBBL | FEATURES PROVIDED | LATCHING CONTACTS |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 1 POLE,DOUBLE THROW,ONE POSITION MOMENTARY |
CRTL | CRITICALITY CODE JUSTIFICATION | FEAT |
CRXH | TIME DELAY | 0.0015 SECONDS MAXIMUM FIXED OPERATE TIME |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 6.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
TEST | TEST DATA DOCUMENT | 81349-MIL-R-39016 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS,BROCHURES,ETC.,THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS,INDUSTRY DIRECTORIES,AND SIMILAR TRADE PUBLICATIONS,REFLECTI |
ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-R-39016/8 GOVERNMENT SPECIFICATION |